****************************************************************************** UT1029: Date 29 oktober 2018 ****************************************************************************** Installed version 1.0.0.1878 - UNITOOL version 1.0.0.1876 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.6.6 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD; German translations updated * MOD; Additional parameters for CI-module MODULE1B ****************************************************************************** UT1028: Date 5 Juli 2018 ****************************************************************************** Installed version 1.0.0.1876 - UNITOOL version 1.0.0.1876 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.6.4 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD Add parameter list function to define user parameter lists. * MOD Obis parameters are add for UNICOM MODEM and UNICOM LOGGER * MOD Second scheduler window for Service scheduler * MOD support of ZST13 parameter typ ****************************************************************************** UT1027: Date 13 Juni 2017 ****************************************************************************** Installed version 1.0.0.1856 - UNITOOL version 1.0.0.1856 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.6.2 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD Removed license of UNITOOL. UNITOOL is started without license * MOD Add parameter C.93.33 to database * BUG Read out of configuration session files in other langauge is now supported. In previous version the wrong values where imported * BUG Windows screen setting of 125% scaling error is solved * MOD Icon is now displayed during startup of application * MOD In case an object returns a error example "ErrorPin" it is still possible to write the value to the meter * MOD In the logger windows the scrolling is set to 12 records. ****************************************************************************** UT1026: Date 29 December 2016 ****************************************************************************** Installed version 1.0.0.1847 - UNITOOL version 1.0.0.1847 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.6.2 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD License is now stored per machine instead of per user. When activate the license it is applied for all users * MOD Response delay on command is increased to 10 seconds * MOD Change in TCP timers; this to improved TCP connectivity * MOD German text parameter C.93.25 "Ein" changed to "LF-signal" * MOD Parameter C.93.1 deleted for UNILOG 300 serial (Device database 1.0.6.2) * BUG In the scheduler window the Start time in de detail window was not changed when the start time in the quick select was changed * BUG The format of time and date of the daily logger was not correct ****************************************************************************** UT1025: Date 18 October 2016 ****************************************************************************** Installed version 1.0.0.1834 - UNITOOL version 1.0.0.1834 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.6.1 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD update .net enviroment to Visual studio 2015 * MOD update visual telerik controls to version 2016 this will probably solve issues with not correct display of left menu control * MOD update .net framework 2.0 to .net Framework 4.6.1 * MOD add support of metertype /WIG5 * MOD Bug the information of scheduler is not imported from settings file. * MOD change of keep alive timeout from 30 seconds to 20 seconds * Device database 1.0.6.1 * MOD change password PWD2 to PWD5 for parameters C.96.1; C.96.2, C.96.3, 7-1:45.11.0 and 7-1:54.11.0 ****************************************************************************** UT1024: Date 2 August 2016 ****************************************************************************** Installed version 1.0.0.1770 - UNITOOL version 1.0.0.1769 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.2 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD Change of time-outs for analog modem connection * MOD some minor text changes ****************************************************************************** UT1023: Date 20 July 2015 ****************************************************************************** Installed version 1.0.0.1769 - UNITOOL version 1.0.0.1769 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.2 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD Add setting "" in file UTSettings.xml to define a temp directory for the databases. The database are copied to this directory. If nothing is defined nothing is copied. This is done to support UNITOOL installed on a Citrix server. ****************************************************************************** UT1022: Date 18 June 2015 ****************************************************************************** Installed version 1.0.0.1764 - UNITOOL version 1.0.0.1764 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.2 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 * MOD Add PDF report for printing and saving settings of UNIGAS 300 * MOD Both common appdata folder or User/AppData/Roaming folder can be used for UNITOOL settings ****************************************************************************** UT1021: Date 16 march 2015 ****************************************************************************** Installed version 1.0.0.1698 - UNITOOL version 1.0.0.1698 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.1 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 - UNITOOL manual version: NL/GB A6 * MOD Company profile changed from Kamstrup to Wigersma & Sikkema * MOD Create of new installshield GUID because change of company name * MOD Temporary files are now save in c:\programdata\ws-gas\Unitool * MOD setting and database files saved in c:\programdata\ws-gas\Unitool * MOD New layer added; TCP\IP for direct connection over ethernet/or local IP modem (MOXA ONCELL G3150) to meter * MOD Possibility to store and recall the session. * MOD Some minor text changes MeterModel database * MOD Add secundaire value for parameter 7-1:54.11.0; Unit kWh/m3 to MJ/m3 (factor 3.6) ****************************************************************************** UT1020: Date 30 January 2015 ****************************************************************************** Installed version 1.0.0.1521 - UNITOOL version 1.0.0.1517 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.1 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 - UNITOOL manual version: NL/GB A6 * MOD "Registration@kamstrup.nl" changed into registration@wigersma-sikkema.com or registration@ws-gas.com ****************************************************************************** UT1019: Date 29 July 2014 ****************************************************************************** Installed version 1.0.0.1517 - UNITOOL version 1.0.0.1517 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.1 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.1 - UNITOOL manual version: NL/GB A6 * MOD Export of loadprofile; Format date text "YYYY-MM-DD" changed into "DD-MM-YYYY" * MOD C.93.12 Type modem configuration can be written * MOD Add device types: - UNILOG MU - UNILOG HM - UNILOG PL - UNIGAS 61E - MODULE 1B * MOD for user "UNIGAS technician" parameter 7-1:42.2.0 is added * MOD Change of text parameter C.98.1 - C.98.20, to arrange the text correctly UnitoolUserModel database * MOD Modbus command time out decreased from 1000 to 300 ms * MOD Modbus ASCII and RTU commando changed to :0006EA600001AF and 0006EA6000017DDD to support disable of modbus in case of other slave address ****************************************************************************** UT1018: Date 11 April 2014 ****************************************************************************** Installed version 1.0.0.1511 - UNITOOL version 1.0.0.1511 - Device database structure version: 0.0.15.0 - Device database content version: 1.0.5.0 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.5.0 - UNITOOL manual version: NL/GB A5 * MOD Function to input secondary value; this can be used for error curve correction * MOD Functions add for MODBUS deactivation, to communicate with device * MOD Improvements of connection screen - Meter type group selection; Now it is not necessary to input device address - No input of serial baudrate and dataformat * MOD The order of the grid is now saved and applies when displaying the grid * BUG Scheduler window the setting of window shorting and/ or month synchronous was not set correctly. * MOD Add meter type MODULE0B for IDOM/ FTP and Modbus protocol * MOD Add general login user "kamstrup" to connect to all meters. * MOD Export of interval data is now stored in csv file (";" separated instead of "|" separated) The file can now displayed in Microsoft Excel. * MOD No need to input serial port dataformat parameters MeterModel database CHG: Parameter C.93.29; Write with PDW2 CHG: Parameter C.93.11; Add option "1,2,3,7,8,9,10,11,14" CHG: Parameter C.92.51 added to product UNILOG GPRS CHG: Add functions for MODBUS CHG: add functions for meter type groups CHG: Add meter type MODULE0B (modbus) ****************************************************************************** UT1017: Date 9 December 2013 ****************************************************************************** Installed version 1.0.0.1394 - UNITOOL version 1.0.0.1392 - Device database structure version: 0.0.14.0 - Device database content version: 1.0.4.3 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.4.0 - UNITOOL manual version: NL/GB A4 * MOD New license component; To solve issues with lost permanent license keys * De-installation of previous versions is needed ****************************************************************************** UT1016: Date 3 September 2013 ****************************************************************************** Installed version 1.0.0.1393 - UNITOOL version 1.0.0.1392 - Device database structure version: 0.0.14.0 - Device database content version: 1.0.4.3 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.4.0 - UNITOOL manual version: NL/GB A4 * MOD Setup changed to MSI installer * MOD The installer will set the user rights of the Kamstrup\Unitool directory * MOD Add language da-DK * BUG fix language nl-NL in handling reading call window settings ****************************************************************************** UT1015: Date 26 November 2012 ****************************************************************************** Installed version 1.0.0.1392 - UNITOOL version 1.0.0.1392 - Device database structure version: 0.0.14.0 - Device database content version: 1.0.4.0 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.4.0 - UNITOOL manual version: NL/GB A4 UNITOOL 1.0.0.1392 * BUG Handling of end time scheduler with 31 days was incorrect * BUG Line between start and and date is moved * CHG End time of restart interval can not be changed ****************************************************************************** UT1014: Date 6 November 2012 ****************************************************************************** Installed version 1.0.0.1383 - UNITOOL version 1.0.0.1383 - Device database structure version: 0.0.14.0 - Device database content version: 1.0.4.0 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.4.0 - UNITOOL manual version: NL/GB A4 UNITOOL 1.0.0.1383 * CHG Scheduler window; Quick select window added * CHG Handling of [NUL] string during initialization of serial port * CHG Handling of DST bit at writing/ reading Time; DST bit is now determined of the date in UNITOOL * CHG Write button enabled after reading the parameters. Used for every menu option * BUG Input of passwords in the connection window are not always applied during the communication with the device Meter database * Add parameter C.91.9 * Add parameter C.93.28 * Add parameter C.93.29 * Changed description C.93.12-> UNILOG GPRS = UNILOG GPRS/300 * Changed parameter C.5; function to write * Changed parameter C.90.6; Format S34v User groep database * Add parameter C.91.9 * Add parameter C.93.28 * Add parameter C.93.29 ****************************************************************************** UT1013: Date 16 march 2012 ****************************************************************************** Installed version 1.0.0.1268 - UNITOOL version 1.0.0.1268 - Device database structure version: 0.0.13.0 - Device database content version: 1.0.3.7 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.7 - UNITOOL manual version: NL/GB A4 Meter database * Add different metertypes UNILOG 300 (03, 04 and 07) * Translations added * Parameter C.93.29 and C.93.28 added User groep database * Assign metertypes UNILOG 300 to user UNILOG. UNITOOL 1.0.0.1268 * BUG In the XML export the value of the parameter was missing * BUG Scheduler window; the start time was not set to 0:00, but was current time * CHG Reading the loggers and storing data is improved * CHG For modem connection also a [CR] command for the connect string is accepted * CHG When resetting a logger the user now has to approve the reset. Message is displayed to perform reset or cancel * CHG Scheduler; The text ON and OFF are added to the window * CHG Report can now be assigned dynamically * CHG The passwords at loggin are now displayed dynamically. Only display the assigned passwords to user instead of a fixed set. ****************************************************************************** UT1012: Date 1 February 2012 ****************************************************************************** Installed version 1.0.0.1224 * Changes in Licensekeys. If the request key was not pressed the information was not saved. * Changes in license generation. It was not always possible to read the PC information. This is handled and an other activation key is generated. ****************************************************************************** UT1011: Date 20 December 2011 ****************************************************************************** Installed version 1.0.0.1223 - UNITOOL version 1.0.0.1221 - Device database structure version: 0.0.13.0 - Device database content version: 1.0.3.6 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.6 - UNITOOL manual version: NL/GB A4 Amount of days for demo version is 90 days instead of 30 days. User group database 1.0.3.5 28-03-2011 * parameter C.93.11 can be written * Add metertype UNILOG 300 (Encoder, puls and serial) with objects and settings Meter database * Add metertype UNILOG 300 (Encoder, puls and serial) with objects and settings * some minor text changes. ****************************************************************************** UT1010: Date 29 march 2011 ****************************************************************************** Installed version 1.0.0.1222 User group database 1.0.3.5 28-03-2011 * Parameter 7-4:0.7.2 can be read and write * parameter 7-1:41.3.0 add to UGTechnician profile * parameterc C.98.1 to C.98.20 (error curve) are add to UGtechnicain profile Some minor text changes. ****************************************************************************** UT1009: Date 17 February 2011 ****************************************************************************** - UNITOOL version 1.0.0.1221 - Device database structure version: 0.0.13.0 - Device database content version: 1.0.3.4 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.4 - UNITOOL manual version: NL/GB A4 Device database 1.0.3.5 26-01-2011 Structure version 0.0.13.0 * Change for UNITOOL version 1.0..1221 * Remove parameter C.1.2 * Change format of C.91.5 from I8 to S16v for track and trace data (integer changed in string) * Add Denmark language with english complete descriptions User group database 1.0.3.4 26-01-2011 Structure version 0.0.5.0 Usergroup UNIGAS 300 * Parameter 7-1:0.2.12 write enabled * Add usergroup UGTechnician for Denmark UNITOOL version 1.0.0.1221 * MOD Position and size of UNITOOL window is saved * MOD Reading the parameters is done by a button ("Read") instead of clicking a menu-item * MOD The colomn of obis code can be switch on and off. Setting is saved * BUG When writing serveral parameters with and without seal protection, and no seal button is pressed, the error status of the parameters are not set correctly. ****************************************************************************** UT1008: Non official release ****************************************************************************** ****************************************************************************** UT1007: Date 18 June 2010 ****************************************************************************** - UNITOOL version 1.0.0.1172 - Device database structure version: 0.0.12.0 - Device database content version: 1.0.3.4 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.3 - UNITOOL manual version: NL/GB A4 * MOD Display date and time in format of PC settings * MOD While reading a parameter a retry in case of an error * MOD Windows 7 tested * MOD It is possible to write the value which is read out of the meter. This is done by clicking the parameter record * MOD parameters added for UNIGAS 300 version 3.1.11 ****************************************************************************** UT1006: Date 01 December 2009 ****************************************************************************** - UNITOOL version 1.0.0.1148 - Device database structure version: 0.0.12.0 - Device database content version: 1.0.3.3 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.2 - UNITOOL manual version: NL/GB A4 * MOD Option add to export/ print the loggers with kolom name the name of the object instead of obis code * MOD Some modems reset the modem after closing the comport. If the echo was on the modem will send the commands back to UNITOOL. This action was not allowed by UNITOOL. Change is made the the modem can echo the commands. After the initialisation string the echo is turned off. * MOD Some modems uses the RTS handshake to check if the data will be accepted. In UNITOOL the RTS handshake was disabled. In this release the RTS handshake for modem and serial is enabled * MOD Some new objects for UNIGAS 300 and UNILOG GPRS are added * BUG Some text changes in the dictonary file * BUG In software version 1.0.01135 the loggings when changing DST settings where not displayed. * BUG Some modems, for example the iTechno, did not function in UNITOOL * BUG In case Vm1 was set to a value UNITOOL will give an unhandeld error while reading the metroligical logbook * BUG Licenses. If a dongle has a MAC address it was possible the UNITOOL uses this MAC address for the registration key When the dongle was not active (not placed in the PC) the MAC address was not available and UNITOOL gots another License Key. This causes that UNITOOL can not be started and the user has to get another license key. In this release UNITOOL this problem is solved. ****************************************************************************** UT1005: Date 02 September 2009 ****************************************************************************** - UNITOOL version 1.0.0.1135 - Device database structure version: 0.0.12.0 - Device database content version: 1.0.3.2 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.1 - UNITOOL manual version: NL/GB A4 * MOD In case of an error message UNITOOL will now be deactivated. * MOD Allowing an empty value in case of an string object with minimum length 0 * BUG In some cases a double logging is displayed when reading out the logger * BUG In some cases the connection status will keep on blinking red * BUG In case when connecting to a device without reading (menu function) and logging off UNITOOL will hang * BUG When setting the dail window a check box is enabled * BUG Bluetooth sometimes causes problems with the registration code ****************************************************************************** UT1004: Date 16 June 2009 ****************************************************************************** - UNITOOL version 1.0.0.1111 - Device database structure version: 0.0.12.0 - Device database content version: 1.0.3.1 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.0 - UNITOOL manual version: NL/GB A4 * BUG Changing languagesettings without logging out give strange behavior * MOD The billing data is not read automatically when logging on to a device * MOD The messageboxen al displayed always on top * MOD No changing of date stamp when opening UNITOOL * MOD Automatically selecting textbox when changing a value * MOD Saving sorting by (categorie/ alpha) and amount of readings. * MOD Display name instead of obis code by intervalloggers and metrological * MOD Minor changes to key value screen * MOD support of UNIGAS 61 mode in UNIGAS 300 ****************************************************************************** UT1003: Date 5 May 2009 ****************************************************************************** - UNITOOL version 1.0.0.1082 - Device database structure version: 0.0.12.0 - Device database content version: 1.0.3.0 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.3.0 - UNITOOL manual version: NL/GB A4 * MOD Display format when changing a parameter of type string * MOD Dispaly message in case password 1 is incorrect * MOD Serveral improvements and bug fixes when password 1 is wrong * MOD Improvements and bug fixes for a modem disconnect * MOD Because some menu item where not available on a screeen 630*800 an scroll function is added. * MOD License key is linked to MACaddress and MachineName. If MACaddress not exists then to CPU ID * BUG Problem with reactive license; The QLM dll are replaced with the latest version IsLicense40.dll 4.1.0.0 new version 4.1.0.0 QlmLicenseLib.dll 4.1.0.18 new version 4.2.0.2 * BUG Add missing translations * BUG Settings of the connection screen are not always saved. * BUG Apply language settings when starting up UNITOOL * BUG If an modem returns an unknown answer, UNITOOL tried to do a reconnect. Now UNITOOL will disconnect and give an error message * BUG If mode C password was incorrect, strange behavior of reading out meterobjects ****************************************************************************** UT1002: Date 1 December 2008 ****************************************************************************** - UNITOOL version 1.0.0.991 - Device database structure version: 0.0.11.0 - Device database content version: 1.0.1.3 - User group database structure version: 0.0.5.0 - User group database content version: 1.0.0.3 - UNITOOL manual version: NL A3 * MOD Function to select language * MOD Add passwords in connection screen * MOD Displaying Database versions in about screen * MOD Display information while reading/ writing/ resetting parameters * MOD Remove kolom date/ time information in Historical logger * MOD The menu-items are now sorted * BUG Resetting the logbook give an error * BUG An error seal give an time out. ****************************************************************************** UT1001: Date 6 November 2008 ****************************************************************************** - First official release of UNITOOL - UNITOOL version 1.0.0.964 - Device database structure version: 0.0.11.0 - Device database content version: 1.0.1.3 ******************************************************************************